Mar 9, 20221 min

The combination of simple elegance, technical skill and economic efficiency

Fire Station Champerret, Paris, France

VISS Fire-Resistant Façades

For the sensitive area of fire protection, Jansen has developed the VISS Fire system – a modular façade construction for universal use. There are numerous options: VISS Fire EI30 Façade , VISS Fire Façade, VISS Fire roof glazing,

The system is suitable for vertical façades in all fire resistance classes for interior and exterior use (E30/60/90, EI30/60/90). All classes are also TRAV safety tested. VISS Fire has also been approved for use with Janisol 2 and Janisol C4 fire doors.

In all cases, contact us early in the design process, Our expertise can be your expertise.

Just The Facts

Tested in accordance with EN 1364

  • Fire protection classes E30 / E60 / E90 / EI30 / EI60 / EI90

  • Successfully TRAV safety tested (German technical
     
    regulations for safety barrier glazing)

  • Face width of 50 and 60 mm

  • Thermal transmittance of Uf > 1.2 W/m2K

  • Basic depths of 50 - 280 mm

  • Infill unit thicknesses of 5 - 70 mm

  • Prefabricated glazing suitable for safety barrier loading in
     
    accordance with DIN 18008-4 Category A and C22

Just in Case You Need a Door or Two

HAT TIP: Jansen Steel Windows, Doors & Façades
 

810